Air-Oxygen Blender

$882.43$1,174.61

SKU: Air-Oxygen Blender

Image may not reflect product configuration.

Precision Medical’s low-flow and high-flow air-oxygen blenders offer unparalleled flexibility, safety, and value. Our innovative, modular systems can be configured to suit various clinical needs within minutes.

The PM5300 series of low-flow air-oxygen blenders is ideal for NICU and PICU settings. This series delivers FiO2 mixtures from two outlet ports and has an overall flow range of 0-30 l/min. The PM5300 series is a highly accurate unit that maintains FiO2 even at low flows.

The PM5200 series of high-flow air-oxygen blenders is intended for use in ER departments, adult ICUs, ORs, and labor and delivery settings. It delivers FiO2 mixtures from two outlet ports and has an overall flow range of 2-120 l/min.

Clinicians have the option to turn the bleed control on or off which provides quieter operation. A large selection control knob is recessed to prevent accidental damage and makes oxygen percentage adjustments straightforward.

The flexible design and available accessories allow for customization. Manage your capabilities as demand and budget warrant. Extend the base blender setup by adding the optional Oxygen Monitor or AccuO2 Oxygen Analyzer to create a complete mixing package.

The Air-Oxygen Blender is easily installed with a universal mounting bracket and can be quickly detached without removing hoses. A unique, interchangeable design reduces routine maintenance time and costs. The infection-control friendly, ABS housing makes the blender durable and effortless to clean. The unit has 8 simple-to-replace components and is easy to service by biomed departments.

For custom outlet configurations and assembly sizes, please contact customer service by using this form or by calling 1-800-272-7285.

 

   Caution! U.S. Federal law restricts this device to sale by or on the order of a physician.

Primary Outlet Flow Range
PM5200 High Flow
15 – 120 l/min
supply pressures at 50 psi (3.4 bar) with BLEED closed

PM5300 Low Flow
3 – 30 l/min
supply pressures at 50 psi (3.4 bar) with BLEED closed

Auxiliary Outlet Flow Range
PM5200 High Flow
20 – 100 l/min
supply pressures at 50 psi (3.4 bar) with BLEED closed

PM5300 Low Flow
0 – 30 l/min
supply pressures at 50 psi (3.4 bar) with BLEED closed

Bleed Flow
PM5200 High Flow
13 l/min or less at 50 psi (3.4 bar)

PM5300 Low Flow
3 l/min or less at 50 psi (3.4)

Maximum Combined Flow (All Outlets)
PM5200 High Flow
≥ 120 l/min

PM5300 Low Flow
≥ 30 l/min

Bypass Flow
(Loss of Air or Oxygen Supply)

PM5200 High Flow
≥ 85 l/min

PM5300 Low Flow
≥ 45 l/min

Bypass Alarm Activation
PM5200 High Flow
50 psi(3.45 bar)
13 – 25 psi (0.9 – 1.7 bar)

PM5200 High Flow
60 psi(4.14 bar)
16 – 24 psi (1.1 – 1.65 bar)

PM5300 Low Flow
50 psi(3.45 bar)
18 – 22 psi (1.2 – 1.5 bar)

PM5300 Low Flow
60 psi(4.14 bar)
16 -24 psi (1.1 – 1.65 bar)

Alarm Reset
When pressure differential is 6 psi (0.4 bar) or less
Alarm Sound Level
≥ to 80 db at 1 ft (0.3 m)
Oxygen Concentration Adjustment Range
21 – 100%
Gas Supply Pressure
30 – 75 psi (2.1 – 5.2 bar) Air and Oxygen
within 10 psi (0.69 bar) of each other
Mixed Gas Stability
± 1% Oxygen
Connection Types
DISS Type – Air & Oxygen Inlets & Outlets and/or NIST Type – Air & Oxygen Inlets
Dimensions (without fittings)
Depth: 4.9 in (12.5 cm)
Width: 2.3 in (5.7 cm)
Height: 4.1 in (10.4 cm)
Weight
Unit Weight: 2.29 lbs (1.04 kg)
Shipping Weight: 2.95 lbs (1.34 kg)
Operating Temperature Range
59°F to 104°F (15°C to 40°C)
Transport/Storage Requirements
Temperature Range: -10°F to 140°F (-23°C to 60°C)

Humidity: Max 95% Non-condensing

FI02 Accuracy
± 3% of full scale
Pressure Drop
Low Flow: ≤ 2 psi (0.14 bar) at inlet pressure from 30 – 90 psi (2.1 – 6.2 bar)
and at 10 l/min flow rate at 60% FI02

High Flow: ≤ 3 psi (0.21 bar) at inlet pressure from 30 – 90 psi (2.1 – 6.2 bar)
and at 30 l/min flow rate at 60% FI02

Pressure Drop Additional Info
The Air-Oxygen Blender has been cleaned for Oxygen Service prior to delivery.

The Air-Oxygen Blender reverse gas flow complies with clause 6 of ISO 11195.

The Oxygen Analyzer should comply with ISO 21647.

Dryness and Composition for Inlet Gases
Air: Medical Air supply should meet the requirements of ANSI Z86.1 – 1973 commodity specification for Air, type 1 grade D or better.Oxygen: Oxygen supply must meet all requirements of USP Medical Grade Oxygen.

Dew Point(ONLY for CE requirements): Both inlets should remain 10°F (5.55°C) or more below the lowest temperature to which the air distribution system equipment is exposed. At a temperature of 25°F (-3.9°C) and a pressure of 90 psi (6.33 kg/cm2) this equates to 2000 mg/m3.

Accuracy of oxygen concentration will be affected if bleed is not activated at flow settings below 15 l/min for the high flow Blender, and 3 l/min for the low flow Blender.

*Specifications are subject to change without prior notice.

You may also like…