3400 Series Continuous-Intermittent 3 Mode

$385.84$485.94

SKU: 3400 Series Continuous-Intermittent 3 Mode

Image may not reflect product configuration.

The Three Mode Continuous & Intermittent model series provides reliable and accurate cycling of the regulator On and Off during the intermittent suctioning. The Three Mode Continuous & Intermittent series has a peak vacuum limit feature to prevent adjusting the vacuum too high. This series is ideal for sensitive applications where limiting Max vacuum is critically important. The intermittent timing cycle is factory set at 16 seconds on and 8 seconds off.

The unique modular design makes repair a breeze for any biomed or central supply department. The unit is made up of eight (8) easy-to-replace modular components.

Unlike the normal plastic inlet and outlet connections on most units, the cast metal backplate connections are extremely durable, thereby saving unnecessary repair costs.

As a result of its modular design, the unit is 25-50% smaller than other suction regulators making it the product of choice for crowded wall and rail areas.

The case is made of strong plastic. It features a smooth surface with rounded corners making cleaning easy. The case also houses the gauge for extra protection.

The large control knob with its three (3) easy-to-read settings make vacuum adjustments simple, even in emergency situations.

The Pediatric vacuum regulator is restricted to 170 mmHg (±10 mmHg) to prevent high vacuum situations and the gauge face is imprinted with the Precision Medical’s “Stork Symbol” to identify the unit for pediatric applications.

Regulator Mode: Continuous-Intermittent 3 Mode (0-150 mmHg)

Custom colors are available. Please call customer service at 1-800-272-7285 for details.

   Caution! U.S. Federal law restricts this device to sale by or on the order of a physician.

Dimensions
Length: 3.7 in (9.4 cm)
Width: 2.8 in (7.1 cm)
Height: 5.2 in (13.2 cm)
Weight: 1.1 lbs (.50 kg)
Gauge Range
PM3400: 0 – 150 mmHg

*PM3400E: 0 – 150 mmHg (0 – 20 kPa)
*Counterclockwise direction
Gauge Accuracy
Analog: ± 5% of MAX

Digital Gauge: ± 1% of Full Scale
Analog Gauge: ± 5% of MAX within ref. Indicator
Vacuum Ports
1/8″ NPT Female
Modes
REG. (Regulated): provides an adjustable, continuous vacuum level

OFF: No Vacuum

INT. (Intermittent): provides an adjustable vacuum level that cycles between ON and OFF
Flow
REG: 50 l/min

INT: 3 l/min

*Maximum flow is obtained with a vacuum source of 21″ Hg (71.1 kPa)
Maximum Vacuum
Restricted to 170 mmHg (23 kPa)
± 10 mmHg (1.3 kPa)
Intermittent Cycle Time
Factory set at sixteen (16) seconds ON and eight (8) seconds OFF (Reference only)
Operating Environmental Limits
0°F to 122°F (-18°C to 50°C)
Recommended Environmental Operating Limits
55°F to 85°F (13°C to 29°C)
Storage Environmental Limits
Temperature Range: -4°F to 140°F (-20°C to 60°C)

Humidity: Max 95% Non-condensing
Battery
Digital Vacuum Gauge Models ONLY
3 Volt Lithium, ½ AA
*Specifications are subject to change without prior notice.