Vacuum Regulators Continuous
The unique modular design makes repair a breeze for any biomed or central supply department. The unit is made up of six (6) easy-to-replace modular components.
Unlike the normal plastic inlet and outlet connections on most units, the cast metal backplate connections are extremely durable, thereby saving unnecessary repair costs.
As a result of its modular design, the unit is 25-50% smaller than other suction regulators making it the product of choice for crowded wall and rail areas.
The case is made of strong plastic. It features a smooth surface with rounded corners making cleaning easy. The case also houses the gauge for extra protection.
The large control knob and easy-to-read settings make vacuum adjustments simple, even in emergency situations.
The Pediatric vacuum regulator is restricted to 170 mmHg (±10 mmHg) to prevent high vacuum situations and the gauge face is imprinted with the Precision Medical's "Stork Symbol" to identify the unit for pediatric applications.
Contact Precision Medical for MR Conditional options.
Custom colors are available. Please call customer service at 1-800-272-7285 for details.
For price inquiries, please use this form.
Specifications
Dimensions
Length: 3.7 in (9.4 cm) |
Width: 2.8 in (7.1 cm) |
Height: 5.2 in (13.2 cm) |
Weight: 1.1 lbs (.50 kg) |
Gauge Range
PM3000: 0 - 200 mmHg - Full Vacuum |
*PM3000E: 0 - 200 mmHg (0 - 26 kPa) |
PM3000HV: 0 - 300 mmHg - Full Vacuum |
PM3100: 0 - 200 mmHg - Full Vacuum |
*PM3100E: 0 - 200 mmHg (0 - 26 kPa) |
*PM3100EHV: 0 - 300 mmHg (0 - 40 kPa) |
PM3100HV: 0 - 300 mmHg - Full Vacuum |
PM3500: 0 - 150 mmHg |
*PM3500E: 0 - 200 mmHg (0 - 26 kPa) |
*Counterclockwise direction |
Gauge Accuracy
Analog: ± 5% of MAX |
Digital Gauge: ± 1% of Full Scale |
Analog Gauge: ± 5% of MAX within ref. Indicator |
Vacuum Ports
1/8 NPT Female |
Modes
PM3100 Series | PM3000 & PM3500 Series |
---|---|
LINE: Provides maximum, continuous vacuum from the vacuum source | |
OFF: No Vacuum | OFF: No Vacuum |
REG. (regulated): provides an adjustable, continuous vacuum level | REG. (regulated): provides an adjustable, continuous vacuum level |
Flow: *PM3000, PM3100 & PM3500
REG | LINE | Note |
---|---|---|
51 L/min | 55 L/min | *MAXIMUM FLOW IS OBTAINED WITH A VACUUM SOURCE OF 21" Hg (71.1 kPa) |
Maximum Vacuum
PM3000 & PM3100: REG. Mode @ Full Vac - 396 mmHg (53 kPa) |
PM3500D: Restricted to 170 mmHg (23 kPa) ± 10 mmHg (1.3 kPa) |
PM3500E: Restricted to 160 mmHg (21 kPa) ± 10 mmHg (1.3 kPa) |
Operating Environmental Limits
0°F to 122°F (-18°C to 50°C) |
Recommended Environmental Operating Limits
55°F to 85°F (13°C to 29°C) |
Storage Environmental Limits
Temperature Range: -4°F to 140°F (-20°C to 60°C) |
Humidity: Max 95% Concondensing |
Battery
3 Volt Lithium, ½ AA (Digital Vacuum Gauge Models ONLY) |
*Specifications are subject to change without prior notice.*
Manuals & Brochures
Manuals
- Continuous and Continuous \ Intermittent Vacuum Regulator User Manual - English (EN)
- Continuous and Continuous \ Intermittent Vacuum Regulator User Manual - Dutch (NL)
- Continuous and Continuous \ Intermittent Vacuum Regulator User Manual - Espanol (ES)
- Continuous and Continuous \ Intermittent Vacuum Regulator User Manual - Italiano (IT)
- Continuous and Continuous \ Intermittent Vacuum Regulator User Manual - German (DE)