Digital Vacuum Regulator

Overview

 

It's Field Serviceable
The unique modular design makes repair a breeze for any biomed or central supply department. The unit is made up of six (6) easy-to-replace modular components.

It's Durable
Unlike the normal plastic inlet and outlet connections on most units, the cast metal backplate connections are extremely durable, thereby saving unnecessary repair costs.

It's Compact
As a result of its modular design, the unit is 25-50% smaller than other suction regulators making it the product of choice for crowded wall and rail areas.

It's Sturdy
The case is made of strong plastic. It features a smooth surface with rounded corners making cleaning easy. The case also houses the gauge for extra protection.

It's User-Friendly
The large control knob and easy-to-read settings make vacuum adjustments simple, even in emergency situations.

It's Safe
The Pediatric vacuum regulator is restricted to 170 mmHg (±10 mmHg) to prevent high vacuum situations and the gauge face is imprinted with the Precision Medical's "Stork Symbol" to identify the unit for pediatric applications.

American Flag

Technical Specifications

Dimensions:
Length: 3.7 in (9.4 cm)
Width: 2.8 in (7.1 cm)
Height: 5.2 in (13.2 cm)
Weight: 1.1 lbs (.50 kg)
Gauge Range: * Counterclockwise direction
PM3000: 0 - 200 mmHg - Full Vacuum
*PM3000E: 0 - 200 mmHg (0 - 26 kPa)
PM3000HV: 0 - 300 mmHg - Full Vacuum
PM3100: 0 - 200 mmHg - Full Vacuum
*PM3100E: 0 - 200 mmHg (0 - 26 kPa)
*PM3100EHV: 0 - 300 mmHg (0 - 40 kPa)
PM3100HV: 0 - 300 mmHg - Full Vacuum
*PM3200E: 0 - 100 kPa (750 mmHg) - Full Vacuum
PM3500: 0 - 150 mmHg
*PM3500E: 0 - 200 mmHg (0 - 26 kPa)
Gauge Accuracy:
Analog: ± 5% of MAX
Digital Gauge: ± 1% of Full Scale
Analog Gauge: ± 5% of MAX within ref. Indicator
Vacuum Ports: 1/8 NPT Female
Modes:
PM3100 & PM3200E Serries:
LINE - Provides maximum, continuous vacuum from the vacuum source
OFF - No Vacuum
REG. - (Regulated) provides an adjustable, continuous vacuum level
PM3000, PM3200E and PM3500 Series:
OFF - No Vacuum
REG. - (regulated) provides an adjustable, continuous vacuum level
Flow: Models Mode Max Flow
*PM3000, PM3100, PM3200 & PM3500:
REG
LINE
51 L/min
55 L/min
*MAXIMUM FLOW IS OBTAINED WITH A VACUUM SOURCE OF 21" Hg (71.1 kPa)
MAXIMUM VACUUM:
PM3000 & PM3100: REG. Mode @ Full Vac - 396 mmHg (53 kPa)
PM3200: REG. Mode @ Full Vac - 100 kPA (750 mmHg)
PM3500D: Restricted to 170 mmHg (23 kPa) ± 10 mmHg (1.3 kPa)
PM3500E: Restricted to 160 mmHg (21 kPa) ± 10 mmHg (1.3 kPa)
Operating Environmental Limits: 0°F to 122°F (-18°C to 50°C)
Recommended Environmental Operating Limits: 55°F to 85°F (13°C to 29°C)
Storage Environmental Limits:
Temperature Range: -4°F to 140°F (-20°C to 60°C)
Humidity: Max 95% Concondensing
Battery: 3 Volt Lithium, ½ AA (Digital Vacuum Gauge Models ONLY)

Specifications are subject to change without prior notice.
*The PM3200E and PM3200E3 are Export Units.*

Manuals

Title Language
English (EN)

Literature

Title Language
English (EN)

Certifications

The PM3000E Series (Digital Vacuum Regulator) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council and all applicable design and safety related standards .

Ordering

Continuous Vacuum Regulator

(Use PM3000, PM3100 and PM3500 as a reference)

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Medical Vacuum Regulator (the Product) will be free of defects in workmanship and/or material for the
following period:

Ten (10) years from date of shipment.

Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and
substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and
standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable
repair or replacement at its own expense.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and
any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the
terms of that contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER
WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits,
lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical,
Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or
change product materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.