Continuous Vacuum Regulator

Overview

It's Field Serviceable.
The unique modular design makes repair a breeze for any biomed or central supply department. The unit is made up of six (6) easy-to-replace modular components.

It's Durable.
Unlike the normal plastic inlet and outlet connections on most units, the cast metal backplate connections are extremely durable, thereby saving unnecessary repair costs.

It's Compact.
As a result of its modular design, the unit is 25-50% smaller than other suction regulators making it the product of choice for crowded wall and rail areas.

It's Sturdy.
The case is made of strong ABS plastic. It features a smooth surface with rounded corners making cleaning easy. The case also houses the gauge for extra protection.

It's User-Friendly.
The large control knob and easy-to-read settings make vacuum adjustments simple, even in emergency situations.

It's Safe.
The Pediatric vacuum regulator is restricted to 170 mmHg (±10 mmHg) to prevent high vacuum situations and the gauge face is imprinted with the Precision Medical's "Stork Symbol" to identify the unit for pediatric applications.

 

 

Proudly Made In the USA.    

Specifications

Dimensions:
Length: 3.7 in. (9.4 cm)
Width: 2.8 in. (7.1 cm)
Height: 5.2 in. (13.2 cm)
Weight: 1.1 lbs. (.50 kg)
Gauge Range:
PM3000 & PM3100: 0-200 mmHg - "Full Vacuum"
PM3500: 0-150 mmHg
*PM3200E: 0 - 100 kPa (750 mmHg) - "Full Vacuum"
Gauge Accuracy:
Analog Display: ±,5% of MAX (within ref. indicator)
Digital Display: ±,1% of Full Scale
Modes:
PM3000 & PM3500: OFF-REG.
PM3100: LINE-OFF-REG.
*PM3200E3: LINE-OFF-REG.
*PM3200E: OFF-REG.
Maximum Vacuum:
PM3000 & PM3100: REG. Mode @ Full Vac- 396 mmHg
PM3500: Restricted to 170 mmHg (±10 mmHg max.)
PM3200: REG. Mode @ Full Vac - 100 kPa (750 mmHg)

Specifications are subject to change without prior notice.

*The PM3200E and PM3200E3 are Export Units.*

Certifications

The PM3000E Series (Continuous Vacuum Regulator) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council and all applicable design and safety related standards.

Ordering

Continuous Vacuum Regulator

(Use PM3000, PM3100 and PM3500 as a reference)

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Medical Vacuum Regulator (the Product) will be free of defects in workmanship and/or material for the
following period:

Ten (10) years from date of shipment.

Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and
substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and
standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable
repair or replacement at its own expense.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and
any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the
terms of that contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER
WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits,
lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical,
Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or
change product materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.