Continuous Subglottic Suction Regulator

Overview

 

It's Innovative
Only unit with the dual capacity of subglottic and continuous suction. This allows clinicians to meet VAP prevention guidelines.

It's Unique
Flow indicator enables the clinician. To rapidly assess the patency of the subglottic suction lumen.

It's Powerful
Out performs traditional suction regulators at low suction pressures used for continuous subglottic suctioning.

It's Compact
Fits into tight headwall systems.

It's User Friendly
Easy to read dial and flow indicator.

American Flag

Technical Specifications

Scaled Suction Range: 0 - 85 mmHg (0 - 11.3 kPa)
Scale Accuracy: ±3 mmHg (.4 kPa)
Maximum Regulator Vacuum Setting: 85 mmHg (11.3 kPa)
Flow: 13 lpm at 20 mmHg up to 37 lpm at Max of 85 mmHg
(54 lpm in "Push to Clear" mode)
Weight (Without Fittings): .38 lbs (.17 kg)
Dimensions (Without Fittings):

All specifications obtained using a vacuum source of 21 inHg (71.1 kPa).

Specifications are subject to change without prior notice.

Vacuum scale & flows are for reference only.

(Verify vacuum pressure setting with PM760 Digital VacCheck).

Literature

Certifications

The PM9100 (Continuous Subglottic Regulator) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council and all applicable design and safety related standards.

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that Continuous Subglottic Suction Regulator (the Product) will be free of defects in workmanship and/or
material for the following period:

Two (2) years from shipment

Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification
thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement at its own expense.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representatives of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described
in this contract, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a
final, complete and exclusive statement of the terms of that contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE OR OTHER WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc, shall not under any circumstances be liable for special, incidental or consequential damages including but not limited
to lost profits, lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of
all liabilities of Precision Medical, Inc. whether based on contract, negligence, strict tort or otherwise.
Precision Medical, Inc. reserves the right to discontinue manufacture of any product or change product materials, designs, or specifications
without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.

Video

Introduction to Subglottic

Using the Subglottic