Oxygen Monitor

Overview

Oxygen MonitorIt’s Intelligent.
It is the only unit which retains settings with batteries removed.

It’s Unique.
It is the only unit to have three different alarm sounds; high/low, check sensor, and low battery alarm.

It’s Durable.
It has a high-impact housing for unparalleled performance under the hardest conditions.

It’s Versatile.
Easy mounting bracket, soft grip sides, and nonskid support feet. Two models available, standard and pediatric.

It’s User-Friendly.
It has a backlit easy-to-read screen and uncomplicated key pad.

It’s a High-Performance Unit.
The highly accurate unit maintains ±1% accuracy.

 

Proudly Made In the USA.    

Specifications

Dimensions:
Length: 1.7 in. (4.4 cm)
Width: 3.6 in. (9.0 cm)
Height: 5.4 in. (13.8 cm)
Cable Length (fully extended): 10 ft (3.1 m)
Weight: Oxygen Monitor, Sensor, Batteries and Cable weight included: 1.11 lbs (0.50 kg)
Operating Conditions:
Temperature: 50°F. to 113°F. (10°C. to 45°C.)
Altitude: Sea Level to 8,000 ft (2,438 m)
Power Requirements: 4 AA Alkaline Batteries (4 x 1.5=6 Volts)
Battery Life: Approximentely 2,000 hours continuous use non-alarm condition
Diverter Fitting: 15 mm "T" adapter
Measurement Range: 0.0 - 100% Oxygen
Accuracy & Linearity: ±1% of full scale at constant temperature, relative humidity and pressure when calibrated at full scale
Total Accuracy: ±3% actual oxygen level over full operating temperature range
Response Time: 90% of final value in less than 12 seconds at 77°F. (25°C.)
Low Battery Indication: "LO BATTERY" message displayed and audible alarm
Low Alarm Range:
PM5900:18% - 99% Oxygen
PM5900L:15% - 99% Oxygen
High Alarm Range:
PM5900:19% - 100% Oxygen
PM5900L:16% - 100% Oxygen
High Alarm De-Activation Setting: Above 100% ("---" will appear)
Sensor Type: Galvanic Oxygen Sensor (fuel cell)

Literature

Certifications

The PM5900 (Oxygen Monitor) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council and all applicable design and safety related standards. Currently the PM5900L (Oxygen Monitor) is not CE approved.

Ordering

Oxygen Monitor

Order Information:
PM5900

Pediatric Oxygen Monitor

Order Information:
PM5900L

Pole Mounts

Order Information:
505014: Horizontal Pole Mount
505013: Vertical Pole Mount

Wall Mount

Order Information:
505189

Tee Adaptor

The Tee Adaptor is used to connect the Oxygen Sensor and Diverter Fitting to a oxygen pathway circuit.
Order Information:
505126

Coil Cable(with Male Plugs)

The Coiled Cable allows the Sensor to be positioned up to 10 ft from the side of the Oxygen Monitor. There are Male Plugs at each end of the Coiled Cable.
Order Information:
504937

Sensor

Galvanic Oxygen Sensor
Order Information:
504877

Diverter Fitting

Fitting used to connect to the Oxygen Source.
Order Information:
505344

Membrane Switch

Order Information:
504926

Battery Door

Order Information:
504909

V Mount Bracket

Order Information:
505010: V Mount Bracket
505120: Screw for V Mount Bracket

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Oxygen Monitor, (the Product), will be free of defects in workmanship and/or material for the following period:

Two (2) years from shipment.

Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof (received by Precision Medical, Inc. within 30 days of the customer’s discovery of the alleged defect), along with return of the Product at the customer’s expense and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct
such defect by repair or replacement (at Precision Medical, Inc.’s option) at its own expense.

Precision Medical, Inc. warrants the 504877 Oxygen Sensor included with the PM5900 Oxygen Monitor to be free from defects in material and workmanship for a
period of sixteen (16) months, from date of shipment. Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof (received by Precision Medical, Inc. within 30 days of the customer’s discovery of the alleged defect), along with return of the sensor at the customer’s expense and substantiation that the sensor has been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the sensor, correct such defect by repair or replacement (at Precision Medical, Inc.’s option) at its own expense. Should a sensor require repair or replacement due to said defects, the sensor is warranted only for the remainder of the original sensor warranty period. A sensor shall not be considered defective for failure to function beyond its normal estimated consumption capacity/rates, and this warranty does not cover normal wear due to consumption beyond the sensor’s estimated O2% hours.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representatives of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this warranty, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the terms of the warranty for the products covered by the applicable contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER
WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits, lost
sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical, Inc. whether
based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or change product
materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.