Technical Specifications

Base Device

Dimensions:
   (Analyzer without Cable and Sensor attached)
Length: 1.30 in (3.32 cm)
Width: 2.90 in (7.30 cm)
Height: 4.00 in (10.23 cm)
Cable Length: 10 ft (3.05 m)(fully extended)
Weight:
Device Weight: 0.35 lbs (5.60 oz / 0.15 kg)
    (includes: Analyzer, Sensor, Cable and batteries)
Electrical Classification: Internally powered Medical Electrical equipment
Operating Conditions:
Temperature: 50°F to 113°F (10°C to 45°C)
Altitude: Sea Level to 8,000 ft
Humidity: 0 - 95% non-condensing
Storage Conditions:
Temperature: 5°F to 122°F (-15&degC to 50°C)
Humidity: 0 - 95% non-condensing
Mode of Operation: Continuous
Diverter Fitting: Diverter fits industry standard, 15 mm Tee Adapter
Measurement Range: 0.00 - 100% Oxygen
Resolution: 0.1%
Total Accuracy: ± 3.0% Actual Oxygen Level over full operating temperature range
Drift of Measurement: < ± 1% of full scale at constant temperature, pressure and humidity
Response Time: 90% of final value in less than 12 seconds at 77°F (25°C)
Warm-up Time: Not required
Low Battery Indication: Low battery icon displayed
Patient Contact: Indirect contact via gas passing through sensor sampling site.
Equipment Classification:
Protection against electric shock: Internally powered equipment
Protection against water: IPX1 (Drip Proof)
Mode of Operation: Continuous
Sterilization: Non-Sterile Device
Flammable anesthetic mixture: Not suitable for use in presence of a flammable anesthetic mixture

*Specifications are subject to change without prior notice.*


Sensor Specifications

Sensor Type: Galvanic Oxygen Sensor; Precision Medical PN 504877
Expected Sensor Life: < 1,000,000 O2 % Hours

*Specifications are subject to change without prior notice.*

Manuals

Title Language
English (EN)

Literature

Title Language
English (EN)

Certifications

The PM5950 (SensO2 Oxygen Sensor Supply) is not currently CE approved.

Ordering

PM5950 Oxygen Monitor

AccuO2 Oxygen Analyzer

    Designed for accurate, reliable and low maintenance measurement of volume percent oxygen.
Order Information:
PM5950
    *Includes Oxygen Analyzer with Coil Cable, Diverter, Sensor and T Piece.*
SensO2 Oxygen Sensor Supply

SensO2 Oxygen Sensor Supply

    The SensO2 Oxygen Sensor Supply is specifically designed for the Precision Medical Line of blenders,
    attaches to the left Primary outlet
Order Information:
PM5300SO
High Flow Helper

High Flow Helper

    The High Flow Helper is versatile triple tubing connection adapter.
Order Information:
1MFAHF
Sensor Tee

Sensor Tee

    The Sensor Tee is specifically designed for the Precision Medical Line of blenders,
    attaches to a flowmeter to complete the line of gas to the patient.
Order Information:
1MFATP
Analyzer Mounting Bracket

Analyzer Mounting Bracket

    This new mounting bracket is durable, lightweight bracket for greater usability. The bracket can be attached to
    both Precision Medical Blenders. The Oxygen Monitor and Analyzer can easily fit into the bracket.
Order Information:
508420
Monitor Pole Mounts

Pole Mounts

Dovetail pole mount.
Order Information:
505014: Horizontal Pole Mount
505013: Vertical Pole Mount
Monitor Wall Mounts

Wall Mount

Dovetail wall mount.
Order Information:
505189
Tee Adaptor

Tee Adaptor

The Tee Adaptor is used to connect the Oxygen Sensor and Diverter Fitting to a oxygen pathway circuit. Single use Sensor Tee piece.
Order Information:
505126
Coil Cable

Coil Cable(with Male Plugs)

The Coiled Cable allows the Sensor to be positioned up to 10 ft from the side of the Oxygen Monitor. There are Male Plugs at each end of the Coiled Cable. Replacement sensor cable for PM5900 and PM5950.
Order Information:
504937
Oxygen Monitor Sensor

Oxygen Sensor

Replacement galvanic oxygen sensor for PM5900 and PM5950.
Order Information:
504877
Diverter Fitting

Diverter Fitting

Sensor diverter, fitting used to connect to the Oxygen Source.
Order Information:
505344
Monitor V Mount Bracket

V Mount Bracket

Rear dovetail replacement for PM5900 and PM5950.
Order Information:
505010: V Mount Bracket
505120: Screw for V Mount Bracket

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Oxygen Analyzer, (the Product), will be free of defects in workmanship and/or material for the following period:

Two (2) years from shipment.

Precision Medical, Inc. is NOT responsible for normal wear and tear, or any neglect or abuse of the product.
The customer is responsible for the shipping costs of repairs back to Precision Medical, Inc.

Precision Medical, Inc. will have in its sole and absolute discretion, the final determination if your product is covered under this limited warranty. Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof (received by Precision Medical, Inc. within 30 days of the customer’s discovery of the alleged defect), along with return of the Product at the customer’s expense and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by repair or replacement (at Precision Medical, Inc.’s option) at its own expense.

Precision Medical, Inc. warrants the 504877 Oxygen Sensor included with the PM5900 Oxygen Analyzer to be free from defects in material and workmanship for a period of sixteen (16) months, from date of shipment. Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof (received by Precision Medical, Inc. within 30 days of the customer’s discovery of the alleged defect), along with return of the sensor at the customer’s expense and substantiation that the sensor has been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the sensor, correct such defect by repair or replacement (at Precision Medical, Inc.’s option) at its own expense. Should a sensor require repair or replacement due to said defects, the sensor is warranted only for the remainder of the original sensor warranty period. A sensor shall not be considered defective for failure to function beyond its normal estimated consumption capacity/rates, and this warranty does not cover normal wear due to consumption beyond the sensor’s estimated O2% hours.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representatives of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this warranty, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the terms of the warranty for the products covered by the applicable contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits, lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical, Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or change product materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.