Pediatric Flowmeters

Overview

 

Black Glass Float Indicator
The black glass float ball enhances visibility in order to assure accurate flow settings.

Durable Housing
The polycarbonate housing is strong and durable. It is impervious to chemical solutions normally used in a clinical setting.

Front Flow Control Knob
The flow control knob is on the front of the flowmeter in clear sight of the operator. Side-mount knobs are susceptible to damage during installation of additional equipment.

Glass Flowtube
The glass flowtube assures consistent readings and allows superb accuracy for precise low-flow requirements.

"Stork" Safety Label.
With the glance of an eye, the stork label quickly identifies the low-flow flowmeter, preventing accidental use of wrong flowmeter in neonatal application.

Shock Protection
The spring above the flowtube and the rubber flow tube bushing absorbs shock to protect the glass tube from breakage.

Warranty
All flowmeters are backed with a five-year warranty on the needle valve and a lifetime warranty on the housing.

American Flag

Technical Specifications

Model Gas Increments Accuracy Max Flush Flow
6MFA1001 Oxygen 20 mL Starts at 20 mL
± 10 mL from 0 - 100 mL
± 14 mL from 100 - 200 mL
500 mL
4MFA1001 Oxygen .1 L/min Starts at .1 L/min ± .05 L/min 5 l/min
1MFA3001 Oxygen
.125 L/min from .125 to 1 L/min
.25 L/min from 1 to 3 L/min
±.15 L/min 40 L/min

Specifications are subject to change without prior notice.

Manuals

Title Language
English (EN)
Swedish (SV)
Danish (DA)
Francais (FR)
Irish (GA)
Polish (PL)
Dutch (NL)
Espanol (ES)
German (DE)
Italiano (IT)
Greek (EL)
Portuguese (PT)

Literature

Title Language
English (EN)
English

Certifications

The 1MFA, 4MFA and 6MFA Flowmeters (Pediatric Flowmeters) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council, Directive 99/36/EC for Transportable Pressure Equipment and all applicable design and safety related standards.

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Medical Gas Flowmeter (the Product) will be free of defects in workmanship and/or material for the following period:

(a) Flow Tube and Housing Lifetime of the product
(b) Needle Valve Five (5) years from shipment
(c) All other parts of the Medical Gas Flowmeter not identified in (a) or (b) above One (1) year from shipment

Warranty does not cover breakage / abuse. Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement at its own expense.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and
any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the
terms of that contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER
WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits,
lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical,
Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or
change product materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.