High-Flow Flowmeters

Overview

High Flow Flowmeters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

American Flag

Technical Specifications

Model Gas Scale Increments (L/min) Accuracy Pressure Flush Flow
0 - 70 L/min Oxygen 0 - 70 L/min 5 L/min (starts at 10 L/min) ± 3 L/min 50 psi 70 - 90 L/min
0 - 70 L/min Air 0 - 70 L/min 5 L/min (starts at 10 L/min) ± 3 L/min 50 psi 70 - 90 L/min

Flowmeters calibrated at 50 psi, 70°F, standard atmospheric pressure.
Accuracy of the 0-70 L/min flowmeter is ± 4 lpm as it approaches 40 L/min.
Specifications are subject to change without prior notice.

Manuals

Title Language
English (EN)
Swedish (SV)
Francais (FR)
Espanol (ES)
German (DE)
Italiano (IT)
Greek (EL)
Portuguese (PT)

Literature

Title Language
English (EN)

Certifications

The 1MFA Flowmeter (High-Flow Flowmeter) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council, Directive 99/36/EC for Transportable Pressure Equipment and all applicable design and safety related standards.

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Medical Gas Flowmeter (the Product) will be free of defects in workmanship and/or material for the following period:

(a) Flow Tube and Housing Lifetime of the product
(b) Needle Valve Five (5) years from shipment
(c) All other parts of the Medical Gas Flowmeter not identified in (a) or (b) above One (1) year from shipment

Warranty does not cover breakage / abuse. Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement at its own expense.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and
any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the
terms of that contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER
WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits,
lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical,
Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or
change product materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.