Dial Flowmeters

Overview

 

They’re Durable
The lack of a flow tube and the durable metal body prevent the breakage problems long associated with standard flowmeters.

They're Compact
The compact size allows the unit to fit into tight headwall areas and makes it virtually damage-proof when other equipment is installed.

They're Accurate
Accuracy is assured at every flow setting without the need for a visible float as in thorpe tube flowmeters.

They're User-Friendly
The knurled flow adjustment knob and the large easy-to-read numbers make flow adjustment easy.

they're Versatile
The unit is available for headwall outlets as well as for ceiling mount drops. It comes in two different flow ranges: .5-15 L/min with flush and 1-25 L/min (both available in oxygen and air).

American Flag

Technical Specifications

Flow Range Settings (lpm) Pressure
0 - 15 L/min Off, .5, 1, 2, 3, 4, 5, 6, 8, 10, 15, and Flush 50 psi
0 - 25 L/min Off, 1, 2, 3, 4, 6, 8, 10, 12, 15, 20, and 25 50 psi

NOTE: There is no flow between settings.


Model Gas Max Flush Flow Increments (L/min)
7MFA1001
7MFA2001
Oxygen
Air
40 - 60 L/min .5, 1, 2, 3, 4, 5, 6, 8, 10, 15 Flush
7MFA1001TC
7MFA2001TC
Oxygen
Air
40 - 60 L/min .5, 1, 2, 3, 4, 5, 6, 8, 10, 15 Flush
7MFA1101
7MFA2101
Oxygen
Air
N/A 1, 2, 3, 4, 6, 8, 10, 12, 15, 20, 25
7MFA1101TC
7MFA2101TC
Oxygen
Air
N/A 1, 2, 3, 4, 6, 8, 10, 12, 15, 20, 25

Flowmeters calibrated at 50psi (3.4 bar), 70°F (21°C0). standard atomspheric pressure.

Accuracy: ± 10% of the indicated flow
Operating Temperature: 69°F to 71°F (20.6°C to 21.6°C)
Storage Temperature: -40°F to 140°F (-40°C to 60°C)
Max Humidity: 95%

Storage/Transport outside the specified range may cause damage to the flowmeter.
Specifications are subject to change without notice.

Manuals

Title Language
English (EN)

Literature

Certifications

The 7MFA (Dial Flowmeters) are not currently CE approved.

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Medical Gas Dial Flowmeter (the Product) will be free of defects in workmanship and/or material for
the following periods:

Five (5) year from shipment

Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and
substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and
standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable
repair or replacement at its own expense.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in
this contract, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and
exclusive statement of the terms of that contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER
WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to
lost profits, lost sales, or injury to person or property. Correction of nonconformities as provided above shall constitute fulfillment of all liabilities
of Precision Medical, Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue
manufacture of any product or change product materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors with out penalty.