Conserving Flowmeter

Overview

Conserving Flowmeter

It’s Versatile.
By combining an oxygen conserver and a flow meter, the clinician is able to choose between Continuous Flow mode and Pulse Dose mode. The outlet connection is the same as a traditional oxygen flowmeter allowing versatility of use.

It Reduces Oxygen Waste.
In the Pulse Dose mode, the EasyPulseFlow operates as an oxygen conserving device, with up to a 5.7 to 1 oxygen conserving ratio.

It Utilizes CMV Technology.
In the Pulse Dose Mode, the EasyPulseFlow uses Precision Medical’s patented Controlled Minute Volume Technology (CMV) that delivers a pulse algorithm wave form, superior trigger sensitivity and fast delivery time. All of this is accomplished with a single lumen cannula. CMV Technology is the most efficient, reliable and clinically sound available today.

It’s Durable.
The polycarbonate housings are extremely durable. They are impervious to chemical solutions normally used in a clinical setting preventing clouding and spidering.

American Flag

Technical Specifications

Dimensions:
Height: 7.9 in (20.1 cm)
Width: 1.9 in (4.8 cm)
Length: 2.5 in (6.4 cm)
Weight:
Unit Weight: 10.4 oz (0.29 kg)
Shipping Weight: 13.6 in (0.39 kg)
Inlet Pressure Range: 50 - 55 psi (3.45 - 3.79 bar)
Pulse Dose Settings: 1, 2, 3, 4 and 5 (Similar FIO2 to Continuous Flow Value)
Continuous Flow Range: 0 - 15 l/min metered (20 - 24 L/min max flush flow)
Pulse Dose Accuracy: Within ± 15% of the normal bolus value (at each breath rate)
Continuous Flow Accuracy:
± 0.25 L/min from 0.5 L/min up to 5 L/min
± 0.5 L/min from 5 L/min up to 15 L/min
Savings Ratio: Up to 5.7 : 1
Trigger Method: Negative inspiratory effort from patient inhalation
Breathing Frequency: Up to 35 bpm
Cannula Requirement: Maximum 7 ft (2.1 m) long standard adult single lumen nasal cannula
Operating Temperature Range: 35°F to 105°F (1.7°C to 40.6°C)
Storage Conditions:
Temperature: -40°F. to 140°F. (-40°C. to 60°C.)
Humidity: Max 95% Noncondensing
Altitude: Sea Level to 10,000 ft (0 to 3,048 m)
Outlet Fitting: 9/16 - 18 UNF Male Threaded Fitting

Specifications are subject to change without prior notice.

Manuals

Title Language
English (EN)

Certifications

The EasyPulse Flow (Conserver Flowmeter) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council and all applicable design and safety related standards.

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the EasyPulseFlow (the Product) will be free of defects in workmanship and/or material for the following periods:

Two (2) years from date of shipment.

Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and
substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard
industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement
at its own expense.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and
any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the
terms of that contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER
WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits,
lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical,
Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or
change product materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.