Compact Flowmeters

Overview

 

They’re Lightweight & Durable
The polycarbonate housing extends over the lightweight aluminum body providing superior durability. The housing is impervious to chemical solutions normally used in a clinical setting.

They're Easy to Read
The state-of-the-art housing incorporates a white background that makes the flow settings easier to read.

They're Compact
The contemporary design results in a smaller unit that fits more easily into space-cramped wall rails. Unlike side-mounted knobs which are susceptible to damage, the flow control knobs are on the front of the flowmeter in clear sight of the operator.

They're Accurate
Our flowmeters use black glass flow indicator balls. The properties of black glass, superior sphericity and exceptionally uniform density, ensure that the flowmeter is more accurate than flowmeters utilizing plastic floats.

they're Dependable
The flow tube has a lifetime warranty and the needle valve carries a five-year warranty.

American Flag

Technical Specifications

Model Flow Range Gas Cal Pressure Cal Temp Graduations Accuracy
Flush
Flow
 
Body
Material
 
Body
Finish
 
Housing
Material
 
Flowtube
Material
 
8MFA1XXX 0 - 15 L/min Oxygen
50 psi
60 psi AU
70°F
.5 (0 - 5)
1 (5 - 15)
0 - 5 ± .25
6 - 15 ± .50
40 - 60
50 - 70
Aluminum Anodized Clear PET Lexan
8MFA2XXX 0 - 15 L/min Air
50 psi
60 psi AU
70°F
.5 (0 - 5)
1 (5 - 15)
0 - 5 ± .25
6 - 15 ± .50
40 - 60
50 - 70
Aluminum Anodized Clear PET Lexan
8MFA4XXX 0 - 8 L/min Oxygen
50 psi
60 psi AU
70°F 5 (0 - 8) 0 - 8 ± .25
40 - 60
50 - 60
Aluminum Anodized Clear PET Lexan

The effect on accuracy of flow due to variations in ambient temperature is standard accuracy +7.3% @ 32°F (0°C) and -3.0% @ 104°F (40°C). The above flowmeter models are calibrated at 50 psi (3.4 bar), 70°F (21°C), and standard atmospheric pressure. International models are calibrated at various pressures specified on the flow tube.

*Specifications are subject to change without prior notice.*

Manuals

Title Language
English (EN)
Swedish (SV)
Danish (DA)
Francais (FR)
Irish (GA)
Polish (PL)
Dutch (NL)
Espanol (ES)
German (DE)
Italiano (IT)
Greek (EL)
Portuguese (PT)

Literature

Certifications

The 8MFA Flowmeter (Compact Flowmeter) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council, Directive 99/36/EC for Transportable Pressure Equipment and all applicable design and safety related standards.

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Medical Gas Flowmeter (the Product) will be free of defects in workmanship and/or material for the following period:

(a) Flow Tube and Housing Lifetime of the product
(b) Needle Valve Five (5) years from shipment
(c) All other parts of the Medical Gas Flowmeter not identified in (a) or (b) above One (1) year from shipment

Warranty does not cover breakage / abuse. Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable repair or replacement at its own expense.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representative of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in this contract, and
any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and exclusive statement of the
terms of that contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER
WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits,
lost sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of Precision Medical,
Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue manufacture of any product or
change product materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.