Air-Oxygen Blender

Overview

 

It's Unique.
It is the only unit available that allows the clinician to turn the bleed control to ON or OFF providing quieter operation. This feature is especially useful in the NICU and PICU.

It's Durable.
The tough ABS housing makes the unit durable and the selection control knob is recessed to prevent accidental damage.

It's Versatile.
The unit is available in two models, high and low flow. The blender is easily mounted with a universal mounting bracket. It can be detached from the mounting bracket without removing hoses.

It's Modular.
The unique modular design can cut routine maintenance time in half as well as reduce maintenance costs. The unit has easy-to-replace modular components and is easily maintained by all biomed departments.

It's User-Friendly.
A large selection control knob makes oxygen percentage adjustments easy. The infection-control-friendly housing is smooth and easy to clean.

It's a High-Performance Unit.
The highly accurate unit maintains FI02 even at low flows. It is economical and provides cost-savings with less waste.

American Flag

Technical Specifications

  PM5200 High Flow PM5300 Low Flow
Primary Outlet Flow Range 15 - 120 L/min 3 - 30 L/min
With both supply pressures at 50 psi (3.4 bar) with BLEED closed
Auxiliary Outlet Flow Range 2 - 100 L/min 0 - 30 L/min
With both supply pressures at 50 psi (3.4 bar) with BLEED closed
Bleed Flow 13 L/min or less at 50 psi (3.4 bar) 3 L/min or less at 50 psi (3.4)
Maximum Combined Flow (All Outlets) ≥ 120 L/min ≥ 30 L/min
Bypass Flow (Loss of Air or Oxygen Supply) ≥ 85 L/min ≥ 45 L/min
Bypass Alarm Activation
50 psi(3.45 bar)
13 - 25 psi
0.9 - 1.7 bar
60 psi(4.14 bar)
16 - 24 psi
1.1 - 1.65 bar
50 psi(3.45 bar)
18 - 22 psi
1.2 - 1.5 bar
60 psi(4.14 bar)
16 -24 psi
1.1 - 1.65 bar
Alarm Reset: When pressure differential is 6 psi (0.4 bar) or less
Alarm Sound Level: ≥ to 80 db at 1 ft (0.3 m)
Oxygen Concentration Adjustment Range: 21 - 100%
Gas Supply Pressure: 30 - 75 psi (2.1 - 5.2 bar) Air and Oxygen within 10 psi (0.69 bar) of each other
Mixed Gas Stability: ± 1% Oxygen
Connection Types: DISS Type - Air & Oxygen Inlets & Outlets and / or NIST Type - Air & Oxygen Inlets
Dimensions:(without fittings)
Depth: 4.9 in (12.5 cm)
Width: 2.3 in (5.7 cm)
Height: 4.1 in (10.4 cm)
Weight:
Unit Weight: 2.29 lbs (1.04 kg)
Shipping Weight: 2.95 lbs (1.34 kg)
Operating Temperature Range: 59°F to 104°F (15°C to 40°C)
Transport / Storage Requirements:
Temperature Range: -10°F to 140°F (-23°C to 60°C)
Humidity: Max 95% Noncondensing
FI0² Accuracy: ± 3% of full scale
Pressure Drop:
Low Flow: ≤ 2 psi (0.14 bar) at inlet pressure from 30 - 90 psi (2.1 - 6.2 bar) and at 10 L/min flow rate at 60% FI0²
High Flow: ≤ 3 psi (0.21 bar) at inlet pressure from 30 - 90 psi (2.1 - 6.2 bar) and at 30 L/min flow rate at 60% FI0²
The Air-Oxygen Blender has been cleaned for Oxygen Service prior to delivery.
The Air-Oxygen Blender reverse gas flow complies with clause 6 of ISO 11195.
The Oxygen Analyzer should comply with ISO 21647.
Dryness and Composition for inlet gases:
Air: Medical Air supply should meet the requirements of ANSI Z86.1 - 1973 commodity specification for Air, type 1 grade D or better.
Oxygen: Oxygen supply must meet all requirements of USP Medical Grade Oxygen.
Dew Point(ONLY for CE requirements: Both inlets should remain 10°F (5.55°C) or more below the lowest temperature to which the air distribution system equipment is exposed. At a temperature of 25°F (-3.9°C) and a pressure of 90 psi (6.33 kg/cm²) this equates to 2000 mg/m³.

* Accuracy of oxygen concentration will be affected if bleed is not activated at flow settings below 15 L/min for the high flow Blender, and 3 L/min for the low flow Blender.
Specifications are subject to change without prior notice.

International Specifications

  PM5300 PM5300M PM5300EN PM5300MEN PM5300NIST
Dimensions (Without Fittings):
Depth: 4.92 in (12.5cm)
Width: 2.25 in (5.7cm)
Height: 4.10 in (10.4cm)
Depth: 4.92 in (12.5cm)
Width: 2.25 in (5.7cm)
Height: 4.10 in (10.4cm)
Depth: 4.92 in (12.5cm)
Width: 2.25 in (5.7cm)
Height: 4.10 in (10.4cm)
Depth: 4.92 in (12.5cm)
Width: 2.25 in (5.7cm)
Height: 4.10 in (10.4cm)
Depth: 4.92 in (12.5cm)
Width: 2.25 in (5.7cm)
Height: 4.10 in (10.4cm)
Weight: 2.9 lbs (1.3kg) 3.4 lbs (1.5kg) 2.9 lbs (1.3kg) 3.4 lbs (1.5kg) 2.9 lbs (1.3kg)
Operating Temperature:
59°F to 104°F
(15°C to 40°C)
59°F to 104°F
(15°C to 40°C)
15°C to 40°C
(59°F to 104°F)
15°C to 40°C
(59°F to 104°F)
15°C to 40°C
(59°F to 104°F)
FiO2 Accuracy: ± 3% of full scale ± 3% of full scale ± 3% of full scale ± 3% of full scale ± 3% of full scale
Bypass Alarm Activation:
18 - 22 psi
(1.2 - 1.5 bar)
18 - 22 psi
(1.2 - 1.5 bar)
1.2 - 1.5 bar
(18 - 22 psi)
1.2 - 1.5 bar
(18 - 22 psi)
1.2 - 1.5 bar
(18 - 22 psi)
Primary Outlet Flow Range: 3 - 30 L/min 3 - 30 L/min 3 - 30 L/min 3 - 30 L/min 3 - 30 L/min
Auxiliary Outlet Flow Range: 0 - 30 L/min 0 - 30 L/min 0 - 30 L/min 0 - 30 L/min 0 - 30 L/min
Bleed Flow:
at 50 psi (3.4 bar)
3 L/min or less 3 L/min or less 3 L/min or less 3 L/min or less 3 L/min or less
Maximum Combined Flow:
(all outlets)
≥ 30 L/min ≥ 30 L/min ≥ 30 L/min ≥ 30 L/min ≥ 30 L/min
No. of Primary
Outlet Ports:
1 3 1 DISS 5 DISS Order separately
No. of Auxiliary Outlet Ports: 1 1 1 DISS 1 DISS Order separately
Inlet Pressure:    
2.1 - 5.2 bar
(30 - 75 psi)
2.1 - 5.2 bar
(30 - 75 psi)
2.1 - 5.2 bar
(30 - 75 psi)
Inlet Fitting:     DISS DISS NIST

NIST Model Outlet Fittings must be ordered separately or installed as needed.
Custom configurations available upon request.
Specifications are subject to change without prior notice.

Literature

Certifications

The PM5200/5300 Series (Air-Oxygen Blender) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council and all applicable design and safety related standards.

Ordering

High Flow Blender

High Flow Air-Oxygen Blender
Order Information:
PM5200
PM5200EN
PM5200NIST
PM5200NISTAP
*EN, NIST and NISTAP Models are CE Certified

High Flow Blender with Manifold

High Flow Air-Oxygen Blender with Manifold
Order Information:
PM5200M
PM5200MEN
*MEN Model is CE Certified

Low Flow Blender

Low Flow Air-Oxygen Blender
Order Information:
PM5300
PM5300EN
PM5300NIST
PM5300NISTAP
*EN, NIST and NISTAP Models are CE Certified

Low Flow Blender with Manifold

Low Flow Air-Oxygen Blender with Manifold
Order Information:
PM5300M
PM5300MEN
*MEN Model is CE Certified

Condensation Trap w/DISS Fitting

Order Information:
PM15-45: Condensation Trap w/DISS Fitting

Wall Mount

Order Information:
504776: Wall Mount

DIN Rail Clamp

Order Information:
505976: DIN Rail Clamp

Pole Mount

Order Information:
504778: Pole Mount

Service/Maintenance Kits

Order Information:
504932: Service Kit for Low Flow Blender with DISS Fittings (Ref PM5300)
505407: Service Kit for High Flow Blender with DISS Fittings (Ref PM5200)
505535: Service Kit for High Flow Blender with NIST Fittings (Ref PM5200)
505534: Service Kit for Low Flow Blender with NIST Fittings (Ref PM5300)
506742: Service Kit for Blender Manifold (Ref Both PM5200 and PM5300)
504827: Service Manual

Picture Coming Soon

Outlet Fitting Kits

Order Information:
505500: Primary Outlet Fitting Kit, DISS with Labale for Low Flow Blender
505499: Auxiliary Outlet Fitting Kit, DISS with Labale for Low Flow Blender
505502: Primary Outlet Fitting Kit, DISS with Labale for High Flow Blender
505501: Auxiliary Outlet Fitting Kit, DISS with Labale for High Flow Blender

Eliminators & Neb Blocks

Order Information:

Flowmeters

Ordering Information:
  Elbow to Left Elbow to Right
0-200cc 6MFA1002-L
0-1 lpm 4MFA1002-L
0-3 lpm 1MFA3002-L
0-5 lpm 1MFA3502-L
0-15 lpm 1MFA1002-L 1MFA1002-R
0-15 lpm 8MFA1002-L 8MFA1002-R
0-15 lpm 7MFA1002-L 7MFA1002-R
0-70 lpm 1MFA8002-L 1MFA8002-R
0-70 lpm with
40 lpm restrictor
1MFA800DR40-L 1MFA800DR40-R

Hose Assemblies

Order Information:
Outlet Type Gas 6 ft. Conductive Hose to Blender Color
DISS Outlet O2 0118/6 ft./9120/0710 Green
Air 0218/6 ft./9121/0218 Yellow
Ohmeda Outlet O2 2111/6 ft./9120/0710 Green
Air 2211/6 ft./9121/0218 Yellow
Chemetron outlet O2 3111/6 ft./9120/0710 Green
Air 3211/6 ft./9121/0218 Yellow

Other outlet configurations and custom assembly sizes available upon request.

Custom Assemblies AvailablePN 069054A Shown

Flowmeters (DISS Inlet Fitting -4 bar 60 psi)

Order Information:
Flowmeters Part No. for
Left Side
Part No. for
Right Side
Part No. for
Straight Fitting
0-200cc with DISS Inlet 6MFA1002AU-L 6MFA1002AU-R 6MFA1002AU
0-1 lpm with DISS Inlet 4MFA1002AU-L 4MFA1002AU-R 4MFA1002AU
0-3 lpm with DISS Inlet 1MFA3002AU-L 1MFA3002AU-R 1MFA3002AU
0-5 lpm with DISS Inlet 1MFA3500AU-L 1MFA3500AU-R 1MFA3500AU
0-15 lpm with DISS Inlet, Brass Body 1MFA1002AU-L 1MFA1002AU-R 1MFA1002AU
0-15 lpm with DISS Inlet, Aluminum Body 8MFA1002AU-L 8MFA1002AU-R 8MFA1002AU

Hose Assemblies

Order Information:
Outlet Fitting
(at Blender)
Inlet Fitting
(at wall)
Gas 2 Meter Conductive Hose to Blender Color
DISS DISS O2 0710/6ft/9120/0118 Green
Air 0218/ 6 ft /9121/0218 Yellow
NIST NIST O2 505780/6ft/9122/505774 White
Air 505775/6ft/9126/505775 Black w/White Strip
NIST DIN O2 505780/6ft/9122/505753 White
Air 505775/6ft/9126/505761 Black w/White Strip

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Blender, (the Product), will be free of defects in workmanship and/or material for the following period:

Two (2) years from shipment

Should any failure to conform to this warranty appear within the applicable period, Precision Medical, Inc. shall, upon written notification thereof and
substantiation that the goods have been stored, installed, maintained and operated in accordance with Precision Medical, Inc.’s instructions and
standard industry practice, and that no modifications, substitutions, or alterations have been made to the goods, correct such defect by suitable
repair or replacement at its own expense.

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES.

The representatives of Precision Medical, Inc. or any retailers are not authorized to make oral warranties about the merchandise described in
this contract, and any such statements shall not be relied upon and are not part of the contract for sale. Thus, this writing is a final, complete and
exclusive statement of the terms of that contract.

THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR
OTHER WARRANTY OF QUALITY, WHETHER EXPRESS OR IMPLIED.

Precision Medical, Inc. shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to
lost profits, lost sales, or injury to person or property. Correction of nonconformities as provided above shall constitute fulfillment of all liabilities
of Precision Medical, Inc. whether based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. reserves the right to discontinue
manufacture of any product or change product materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.