PM2200 EasyMate Liquid Oxygen System

Overview

PM2200 EasyMate Liquid Oxygen SystemIt's New Technology.
The EasyMate utilizes a new patented technology that provides a safer, more efficient and reliable means of delivering liquid oxygen.

It Has Dependable Use Time.
The EasyMate utilizes out patented controlled minute volume technology to provide dependable use time of up to 9 hours reducing the amount of patient deliveries.

It's Safe.
Once filled, the EasyMate can only release gaseous oxygen preventing the chance of a liquid oxygen hazard, making it the safest unit available.

It's Durable.
The rugged material and unique product design make the EasyMate more durable while remaining lightweight.

It's Clinically Sound.
It delivers a front loaded tapered wave form and the entire bolus of oxygen is delivered in the first third of the inspiratory phase.

It Utilizes Single Lumen Cannulas.
The EasyMate's patented pneumatic technology utilizes a single lumen cannula reducing costs to the provider.

It Reduces Fill Time.
The fill time for the EasyMate is one half of other liquid oxygen units resulting in shorter patient exposure time.

It's Compatible.
The EasyMate is compatible with base units with PB, Mark series and Caire fill connectors making filling easy regardless of head pressure.

 

Proudly Made In the USA.  

Specifications

Dimensions:
Length: 4.8" (12.2 cm)
Width: 3.6" (9.2 cm)
Height: 8.2" (20.8 cm)
Weight (filled unit without Carry Bag): 3.6 lbs (1.6 kg)
Operating Temperature Range: 35°F. to 110°F. (1.7°C. to 43.3°C.)
Storage Temperature Range: -10°F. to 140°F. (-23°C. to 60°C.)
Operating Altitude Range: 500 ft below sea level to 10,000 ft (152 m below sea level to 3,048 m)
Fill Source Pressure: Up to 50 psi (3.5 bar)
Fill Time: 25 sec. approx. (average from 22 psi (1.5 bar) fill source)
Cannula Requirements: Standard adult single lumen up to 7 ft (2.1 cm) in length

Certifications

The PM2200 (EasyMate LOX) meets or exceeds the requirements of the Medical Device Directive(MDD), Council Directive 93/42/EEC Concerning Medical Devices, Directive 2007/47/EC of The European Parliament and Council, Directive 99/36/EC for Transportable Pressure Equipment and all applicable design and safety related standards.

Ordering

EasyMate Portable (Puritian-Bennett)

EasyMate Liquid Oxygen System (w/Puritan Bennet Fill Connector) with 1 Adult Single Lumen Cannula 4ft. (1.2m), Carry Bag, and Scale
Order Information:
PM2200
PM2200CE
PM2200DE
PM2200EN
PM2200ES
PM2200FR
*CE, DE, EN, ES and FR Models are CE Certified

EasyMate Portable (Mark Series)

EasyMate Liquid Oxygen System (w/Mark Series Fill Connector) with 1 Adult Single Lumen Cannula 4ft. (1.2m), Carry Bag, and Scale
Order Information:
PM2201

EasyMate Portable (Caire)

EasyMate Liquid Oxygen System (w/Caire Fill Connector) with 1 Adult Single Lumen Cannula 4ft. (1.2m), Carry Bag, and Scale
Order Information:
PM2202
PM2202CE
PM2202DE
PM2202EN
PM2202ES
PM2202FR
*CE, DE, EN, ES and FR Models are CE Certified

Cannula

Single Lumen Cannula, Nasal, High Flow - 4ft. (1.2m) comes in a case of 25
Order Information:
504833-25

Carry Bag, Complete (PM2200 Series)

Order Information:
504392

Contents Scale (PM2200 Series)

Order Information:
504393
 

Waist Strap

Order Information:
504615
 Picture Coming Soon.

Shoulder Strap

Order Information:
504629

Warranty

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Precision Medical, Inc. warrants that the Precision Medical Liquid Oxygen System (the Product) and the following component parts thereof will be free of defects in
workmanship and/or material for the following period:

EasyMate Liquid Oxygen System One (1) year from date of shipment

Vessel Vacuum Five (5) years from date of shipment

 

This limited warranty does not cover:
1) Normal routine service items,
2) Defects due to the wear and tear caused by mating components,
3) Repair or replacement necessitated by misuse, abuse, or accident.

Replacement parts or repaired products shall be free from defects in workmanship and materials for the duration of the unexpired portion of the original warranty or ninety (90) days from the date of reshipment, whichever is longer. Should any failure to conform to this warranty appear within the applicable period,
Precision Medical, Inc. shall, upon written notification thereof and substantiation that the goods have been stored, installed, maintained and operated in accordance
with Precision Medical, Inc.’s instructions, operational verification procedures, and standard industry practice, and that no modifications, substitutions, or alterationshave been made to the goods, shall, in its discretion, and at its own expense, repair or replace the defective component(s).

 

ORAL STATEMENTS DO NOT CONSTITUTE WARRANTIES AND THERE ARE NO WARRANTIES OTHER THAN AS SET FORTH IN THIS CONTRACT.

Neither the representative of Precision Medical, Inc. nor any retailers are authorized to make oral warranties about the merchandise described in this contract, and any such statements shall not be relied upon and are not part of the contract for sale. This writing is a final, complete and exclusive statement of the terms of the contract and sale. Precision Medical, Inc. Disclaims any warranty of merchantability, fitness for a particular purpose or any other warranty of quality, whether express or implied except as set forth above.

Precision Medical, Inc. Shall not under any circumstances be liable for special, incidental or consequential damages including but not limited to lost profits, lost
sales, or injury to person or property. Correction of non-conformities as provided above shall constitute fulfillment of all liabilities of precision medical, inc. Whether
based on contract, negligence, strict tort or otherwise. Precision Medical, Inc. Reserves the right to discontinue manufacture of any product or change product
materials, designs, or specifications without notice.

Precision Medical, Inc. reserves the right to correct clerical or typographical errors without penalty.